Voice Internet Phone Gateway User Manual IPC 1000 Series version:1.0 update date:2003/12/21 ARTDio Company Inc.
ARTDio IPP 1000 Series 93. PANEL FEATURES 3-1 FRONT PANEL The IPP Series VoIP Gateway is a 19 inch modularized unit. Each unit has 2 Ethernet po
ARTDio IPP 1000 Series 103-3.1 INDICATOR DESCRIPTION LED Label Indication Description On Link Up Link/ACT Flash Sending/Receiving data Package
ARTDio IPP 1000 Series 114. BASIC INSTALLATION 4-1 HARDWARE CONNECTIONS 4-1.1 Connect Power and Telephone Lines 4-1.2 PC Connection
ARTDio IPP 1000 Series 124-2 CONFIRMING and/or CHANGING REGION ID If you are installing your IPP unit in the default region, you may skip this pr
ARTDio IPP 1000 Series 13IP Environment Required Information Public IP address IP address Subnet mask Default Gateway It is recommended that you
ARTDio IPP 1000 Series 144-2.3 SETTING THE WEB PAGE PASSWORD Before entering the WEB Management Page first set the password to prevent unauthoriz
ARTDio IPP 1000 Series 15Setting phone number on web page:/ BASIC / My Phone Number In the field ‘My Phone Number’, will appear the country c
ARTDio IPP 1000 Series 165. SETTING FUNCTIONS 5-1 Inter-System Calls With the IPP Series, you can call other IPP units, and connect to the IPE s
ARTDio IPP 1000 Series 17Parameters for example above Setting Place: Taipei IPP Place: USA IPP Telephone Number 886-2-8226-8888 1-644-1234567
ARTDio IPP 1000 Series 18 Select CHANNEL\CONFIGURATION to bring up the following page: 1. Select Channel in the ‘Channel’ field drop-down box
ARTDio IPP 1000 Series 1Safety Instructions Warning 1. Do not attempt to service or repair the product. Any servicing or repair of this equipm
ARTDio IPP 1000 Series 195-2.1 Assigning Trunk Group Access Code Select the ‘ADVANCED / NUMBERING PLAN’ icons on the Web Management page. Ass
ARTDio IPP 1000 Series 205-2.2 Assigning In-Coming FXO line to a Trunk Group Select ‘CHANNEL \ CONFIGURATION ‘ on the Web Management Page Sel
ARTDio IPP 1000 Series 21Call Transfer Dialing Method Destination Transfer Procedure Example Internal Extension Flash button + extension 14 Ano
ARTDio IPP 1000 Series 22 5-5 Call Forward Any IPP extension can forward a call to: Any extension on the local IPP unit Any other IPP exten
ARTDio IPP 1000 Series 23 Dialing Procedures 5-6 Operator Setting the operator code Select ‘ADVANCED \ NUMBERING PLAN’ on the Web Managemen
ARTDio IPP 1000 Series 245-7 Speed Dial The IPP series has a speed dial memory capacity of 100 phone numbers. The phone number can be set from an
ARTDio IPP 1000 Series 25Setting the speed dial phone number: Select ‘BASIC \ SPEED DIAL’ on the Web Management Page Enter the desired number
ARTDio IPP 1000 Series 26 5-8 VoIP Calls Budget Control IPP series units operate under the G.729AB protocol with voice packets of 40ms with each
ARTDio IPP 1000 Series 275-9 Outbound Transit Calls The IPP series is capable of forwarding calls from IPH/IPC/IPE series units to local PSTN. As
ARTDio IPP 1000 Series 28 5) Select ‘ ADVANCED \ TRUNK GROUP’ on the Web Management Page 6) In the ‘Remote Access’ field drop-down box select ‘T
ARTDio IPP 1000 Series 2 Table of Contents SAFETY INSTRUCTIONS --------------------------------------
ARTDio IPP 1000 Series 29 10) Click ‘Apply’ 5-10 Inbound Transit Calls Incoming calls to IPP unit can be transferred to IPH/IPC/IPE, and IPP uni
ARTDio IPP 1000 Series 30886-2-26951111 Carrier Setting the Inbound Transit Password: 1) Select ‘BASIC \ INBOUND TRANSIT’ on the Web Management P
ARTDio IPP 1000 Series 31IP 1-644-1234567886-2-8226-8888 Taipei IPH IPP 886-2-26951111 Carrier x11 x22 … IPP Carrier x11x22 … IPN ID 111IPN IPE BJ
ARTDio IPP 1000 Series 32Auto-Attendant Recording Commands 1. Pick up the phone, listen for dial tone, dial ##9999 after hearing confirmation res
ARTDio IPP 1000 Series 335-14.1 Create a Barring Class 1. Select a barring class in the Class Entry in the ‘Class Information’ field and click
ARTDio IPP 1000 Series 34 Example 4: Assuming the device is located in Tokyo (Japan), the setting shown below only allows local calls. Long distan
ARTDio IPP 1000 Series 35 5-15 CALLING RECORD SMDR All calls through the IPP series units via FXO ports will automatically generate a call deta
ARTDio IPP 1000 Series 366. WEBPAGE EXPLANATION 6-1 Basic
ARTDio IPP 1000 Series 376-1.1 General Section Item Field Description Default Region ID Refers to the country in which the unit is operating (
ARTDio IPP 1000 Series 386-1.2 Inbound Transit Section Item Field Description Default Maximum Maximum number of entries allowed. (Read O
ARTDio IPP 1000 Series 35-2.1 Assigning Trunk Group Access Code----------------------------------------------------------------------------------
ARTDio IPP 1000 Series 396-1.3 Outbound Transit Section Item Field Description Default Maximum Maximum number of entries allowed (Read Only
ARTDio IPP 1000 Series 406-1.4 Off-net Forward Section Item Field Description Default Maximum Maximum number of entries allowed for off-net
ARTDio IPP 1000 Series 416-1.5 Speed Dial Section Item Field Description Default Total Entries The maximum entries that can be set 100 En
ARTDio IPP 1000 Series 426-1.6 Barring Class Section Item Field Description Default Class Entry Select barring class from ‘Class Entry’ fi
ARTDio IPP 1000 Series 43Section Item Field Description Default Class Attribute The class attribute can be set to either “Deny” or “Accept”. Bo
ARTDio IPP 1000 Series 446-2 IP Settings
ARTDio IPP 1000 Series 45Section Item Field Description Default IP State Method of obtaining: Manual: Entered by user (Static IP) Auto(DHCP): A
ARTDio IPP 1000 Series 466-3 Advanced 6-3.1 General Section Item Field Description Default Flash Button Flash Time Set the flash time dur
ARTDio IPP 1000 Series 476-3.2 Numbering Plan Section Item Field Description Default IP Call Auto Learning Will automatically learn IP cal
ARTDio IPP 1000 Series 486-3.3 Trunk Group Section Item Field Description Default Member Assignment of in-coming line to trunk group 1 4
ARTDio IPP 1000 Series 46-3 Advanced-------------------------------------------------------------------------------------------------------------
ARTDio IPP 1000 Series 496-4 Channel 6-4.1 Summary Section Item Field Description Default SUMMARY Channel Lists the channels, and extens
ARTDio IPP 1000 Series 506-4.2 Configuration Section Item Field Description Default Channel Select channel/extension to be configured 1/1
ARTDio IPP 1000 Series 516-5 Phone Book Section Item Field Description Default Phone Number Enter the phone number to find the IP address
ARTDio IPP 1000 Series 526-6 Access Code
ARTDio IPP 1000 Series 53Section Item Field Description Default Outgoing Call Carrier Selection (International) Access Code Enter the internati
ARTDio IPP 1000 Series 547. Special Applications 7-1 Using NAT Via Private IP IPP can be configured as a private IP address and inter-connecte
ARTDio IPP 1000 Series 557-1.2 Tested IP Sharing Devices Although the IPP unit works with most commonly used IP sharing devices, there are stil
ARTDio IPP 1000 Series 567-1.3 IP Sharing Devices Not Recommended The following IP Sharing devices have been tested and have been found not to wo
ARTDio IPP 1000 Series 578. FILE MANAMEMENT 8-1 File Type File File Type Description HFIPPX.CFG System Configuration System Configuration HFI
ARTDio IPP 1000 Series 58 2. Selecting ‘Connect’ will synchronize the PC and IPP systems. A successful connection will call up the Gateway File.
ARTDio IPP 1000 Series 512. APPENDIX --------------------------------------------------------------------------------------------- 66 12-1 Lis
ARTDio IPP 1000 Series 594. Select ‘Overwrite’ 5. After selecting ‘Overwrite’, check to insure the time and date are the same. Return to the
ARTDio IPP 1000 Series 609. NETWORK MANAGEMENT 9-1 Use Of The System Console 9-1.1 System Command Summary User Exec commands:
ARTDio IPP 1000 Series 619-2 Use Of The Web Management Page Use console to configure IP information and open the web page using the configured
ARTDio IPP 1000 Series 6210. INTER-CONNECTION VIA IPN When IPP is configured as a IPN IP and port number, the IPP will join the IPN group. IPN mu
ARTDio IPP 1000 Series 63 10-2 IPP Setting IPN IP
ARTDio IPP 1000 Series 6410-3 IPP WEB PAGE Open the web page to confirm the setting is working. Select BASIC/GENERAL
ARTDio IPP 1000 Series 6511. Specifications Number of ports 4 FXO + 12FXS FAX relay T.30/T.38 FXS interface Transport protocols FXO interfac
ARTDio IPP 1000 Series 6612. Appendix 12-1 List of Region ID By Country ID NO. Country ID NO. Country ID NO. Country ID NO. Country 01 A
ARTDio IPP 1000 Series 61. PREFACE IPP is the latest in communication technology, combing PBX and VoIP functions. The system enables no cost tele
ARTDio IPP 1000 Series 71-2 ADDITIONAL IPP FEATURES Transit-in Call for Remote Use: When away from home or office, you may call into your IPP
ARTDio IPP 1000 Series 82. PACKAGE CONTENTS VoIP Gateway AC power adapter with cable Mounting rack CD-ROM 8 IDC connectors